Welding System Internal Audit Checklist
Controlled master
The controlled master is the file on the IDM server, at the location shown above.
Download it here; the text below is a convenience rendering of the same document.
Where the two differ, the server file governs.
Conducted annually under QP02 by a competent auditor independent of the activity audited. This checklist supplies the welding content; the audit process, reporting and follow-up remain those of QP02.
| Audit date |
|
Auditor |
|
| Areas audited |
|
Report ref |
|
A. System and coordination
| Question |
Evidence to seek |
C / NC / OFI |
Finding |
Ref |
| Is the current revision of IDM-FPC-WQM-001 in use, and are superseded revisions withdrawn? |
Manual, master document register |
|
|
|
| Is the RWC appointment current, with competence evidence on file and verified? |
WMS-A-05, IWE/EWE certificate |
|
|
|
| Has the RWC exercised coordination in every period since the last audit? |
Welding activity log — look for gaps |
|
|
|
| Are the monthly, quarterly and annual cadence items in Section 16 all evidenced? |
Welding activity log |
|
|
|
| Is the deputy arrangement in place and has it ever been used? |
WMS-A-05, activity log |
|
|
|
| Have referrals to the RWC been answered in writing within the agreed response time? |
Coordination correspondence |
|
|
|
| Is the scope of certification statement current and does actual work fall inside it? |
WMS-A-02, recent job files |
|
|
|
B. Personnel
| Question |
Evidence to seek |
C / NC / OFI |
Finding |
Ref |
| Does every welder working on certified product hold a current qualification? |
Welder qualification register, certificates |
|
|
|
| Are continuity confirmations signed within the required interval for every welder? |
Continuity confirmation records |
|
|
|
| Take three welds at random — was the welder qualified for that WPS on that date? |
Weld log, allocation record, certificates |
|
|
|
| Is the welder ID and stamp roster current and does it match the weld log? |
WMS-C-08, weld logs |
|
|
|
| Is inspection and NDT personnel certification current, IDM and sub-contract? |
Personnel certificates |
|
|
|
| Where the internal coordinator welds, was an independent inspector used? |
Allocation records, inspection records |
|
|
|
| Is the competence matrix current and are training actions closed? |
WMS-D-10 |
|
|
|
C. Procedures and qualification
| Question |
Evidence to seek |
C / NC / OFI |
Finding |
Ref |
| Is every WPS in production use supported by a valid WPQR? |
WPS and WPQR registers |
|
|
|
| Is every WPS signed by the RWC at its current revision? |
WPS set |
|
|
|
| Are superseded WPS and retired WPQR out of circulation? |
Superseded folders, workstations |
|
|
|
| Do the welding stations hold the correct current WPS? |
Physical check at the booth |
|
|
|
| Is every material and filler combination welded covered by the approval matrix? |
WMS-C-09, weld logs, job files |
|
|
|
| Has any out-of-scope combination been welded since the last audit? |
Job files, NCRs, activity log |
|
|
|
D. Production control
| Question |
Evidence to seek |
C / NC / OFI |
Finding |
Ref |
| Take two recent jobs — is the contract and technical review complete and signed? |
Job folders |
|
|
|
| Was the weld map produced and approved before welding started? |
Job folders |
|
|
|
| Is the weld log completed as work proceeded, or reconstructed afterwards? |
Weld log — check handwriting, ink, date sequence |
|
|
|
| Is material traceable from certificate through cutting to the finished weld? |
Material certs, issue records, weld log |
|
|
|
| Is consumable batch traceable to the weld? |
Consumable issue record, weld log |
|
|
|
| Are storage condition checks being recorded? |
Storage condition records |
|
|
|
| Is welding plant within calibration and is expired plant withdrawn? |
Calibration register, physical check |
|
|
|
| Question |
Evidence to seek |
C / NC / OFI |
Finding |
Ref |
| Was 100% visual inspection carried out and recorded on every contract? |
Visual inspection records |
|
|
|
| Was NDT carried out to the extent required by the inspection class? |
ITP, NDT reports |
|
|
|
| Are welding NCRs referred to the RWC and dispositions authorised by him? |
NCR register, NCR records |
|
|
|
| Were weld repairs carried out to an approved repair procedure? |
NCR records, repair WPS |
|
|
|
| Is the documentation pack complete before dispatch? |
Release notes, job folders |
|
|
|
| Is the certificate of conformity signed by the correct authority? |
Release notes |
|
|
|
F. Standards and customer requirements
| Question |
Evidence to seek |
C / NC / OFI |
Finding |
Ref |
| Is the controlled standards register current and has it been checked this year? |
WMS-A-11 |
|
|
|
| Is any standard in use superseded? |
WMS-A-11, physical copies |
|
|
|
| Are customer standards held at the revision the customer currently requires? |
WMS-D-11, customer correspondence |
|
|
|
C = conforms · NC = non-conformance, raise under QP03 · OFI = opportunity for improvement. Every NC is entered in the welding activity log as well as the QP03 register.
| Role |
Name |
Signature |
Date |
| Auditor |
|
|
|
| RWC — reviewed |
|
|
|
| General Manager — actions accepted |
|
|
|